Review




Structured Review

LecTec Corporation electrocardiogram gel electrodes
Electrocardiogram Gel Electrodes, supplied by LecTec Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/electrocardiogram gel electrodes/product/LecTec Corporation
Average 90 stars, based on 1 article reviews
electrocardiogram gel electrodes - by Bioz Stars, 2026-05
90/100 stars

Images



Similar Products

86
Covidien electrocardiogram electrode contact gel
Electrocardiogram Electrode Contact Gel, supplied by Covidien, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/electrocardiogram electrode contact gel/product/Covidien
Average 86 stars, based on 1 article reviews
electrocardiogram electrode contact gel - by Bioz Stars, 2026-05
86/100 stars
  Buy from Supplier

93
ADInstruments gel electrodes
a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of ECG signals acquired by fibre and gel <t>electrodes</t> at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).
Gel Electrodes, supplied by ADInstruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/gel electrodes/product/ADInstruments
Average 93 stars, based on 1 article reviews
gel electrodes - by Bioz Stars, 2026-05
93/100 stars
  Buy from Supplier

93
ADInstruments disposable ecg gel electrodes
a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of <t>ECG</t> signals acquired by fibre and gel <t>electrodes</t> at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).
Disposable Ecg Gel Electrodes, supplied by ADInstruments, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/disposable ecg gel electrodes/product/ADInstruments
Average 93 stars, based on 1 article reviews
disposable ecg gel electrodes - by Bioz Stars, 2026-05
93/100 stars
  Buy from Supplier

90
Unomedical Ltd ag/agcl gel-coated electrocardiogram electrodes
a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of <t>ECG</t> signals acquired by fibre and gel <t>electrodes</t> at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).
Ag/Agcl Gel Coated Electrocardiogram Electrodes, supplied by Unomedical Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/ag/agcl gel-coated electrocardiogram electrodes/product/Unomedical Ltd
Average 90 stars, based on 1 article reviews
ag/agcl gel-coated electrocardiogram electrodes - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Agilent technologies liquid gel silver/silver chloride (ag/ gcl) electrocardiogram (ecg) electrodes
a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of <t>ECG</t> signals acquired by fibre and gel <t>electrodes</t> at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).
Liquid Gel Silver/Silver Chloride (Ag/ Gcl) Electrocardiogram (Ecg) Electrodes, supplied by Agilent technologies, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/liquid gel silver/silver chloride (ag/ gcl) electrocardiogram (ecg) electrodes/product/Agilent technologies
Average 90 stars, based on 1 article reviews
liquid gel silver/silver chloride (ag/ gcl) electrocardiogram (ecg) electrodes - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
LecTec Corporation electrocardiogram gel electrodes
a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of <t>ECG</t> signals acquired by fibre and gel <t>electrodes</t> at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).
Electrocardiogram Gel Electrodes, supplied by LecTec Corporation, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/electrocardiogram gel electrodes/product/LecTec Corporation
Average 90 stars, based on 1 article reviews
electrocardiogram gel electrodes - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
BioSemi electrocardiogram (ecg) with two ag/ag-cl-electrodes filled with isotonic electrode gel
a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of <t>ECG</t> signals acquired by fibre and gel <t>electrodes</t> at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).
Electrocardiogram (Ecg) With Two Ag/Ag Cl Electrodes Filled With Isotonic Electrode Gel, supplied by BioSemi, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/electrocardiogram (ecg) with two ag/ag-cl-electrodes filled with isotonic electrode gel/product/BioSemi
Average 90 stars, based on 1 article reviews
electrocardiogram (ecg) with two ag/ag-cl-electrodes filled with isotonic electrode gel - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Leonhard Lang GmbH wet gel electrocardiogram (ecg) electrodes skintact
a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of <t>ECG</t> signals acquired by fibre and gel <t>electrodes</t> at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).
Wet Gel Electrocardiogram (Ecg) Electrodes Skintact, supplied by Leonhard Lang GmbH, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/wet gel electrocardiogram (ecg) electrodes skintact/product/Leonhard Lang GmbH
Average 90 stars, based on 1 article reviews
wet gel electrocardiogram (ecg) electrodes skintact - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

Image Search Results


a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of ECG signals acquired by fibre and gel electrodes at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).

Journal: Nature Electronics

Article Title: Imperceptible augmentation of living systems with organic bioelectronic fibres

doi: 10.1038/s41928-024-01174-4

Figure Lengend Snippet: a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of ECG signals acquired by fibre and gel electrodes at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).

Article Snippet: The gel electrodes used as references were commercial disposable ECG Electrodes (ADInstruments).

Techniques: Comparison, Standard Deviation

a , Augmented touch perception via dual-ECG sensing with person-i wearing bioelectronic fibre arrays and person-ii without. The dual-ECG signal acquired through the fibre array is compared with the reconstructed composite-ECG signal from validation gel electrodes. The red downward facing and green upward facing triangles indicate the R peaks of person-i and person-ii, respectively. b , A breathable skin-gated OECT on a fingertip; the OECT displays a response time in the 60 s range. c , Dual-modal sensing for augmented perception of mist pulses with acidic, alkaline and neutral compositions distinguished through colorimetric and electrical readouts. The mist pulse photographs show an example of a neutral mist pulse, and the fibre resistance change was recorded by applying three consecutive neutral mist pulses (normalized resistance change is calculated as \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{R}^{* }-{R}_{0}}{{R}_{0}}$$\end{document} R * − R 0 R 0 , where R* is the peak resistance and R 0 is the initial resistance; the initial resistances of the fibre arrays are in the range of 10 kΩ). a – c , Typical results from n = 5 volunteers, with n > 3 independent experiments performed on each volunteer.

Journal: Nature Electronics

Article Title: Imperceptible augmentation of living systems with organic bioelectronic fibres

doi: 10.1038/s41928-024-01174-4

Figure Lengend Snippet: a , Augmented touch perception via dual-ECG sensing with person-i wearing bioelectronic fibre arrays and person-ii without. The dual-ECG signal acquired through the fibre array is compared with the reconstructed composite-ECG signal from validation gel electrodes. The red downward facing and green upward facing triangles indicate the R peaks of person-i and person-ii, respectively. b , A breathable skin-gated OECT on a fingertip; the OECT displays a response time in the 60 s range. c , Dual-modal sensing for augmented perception of mist pulses with acidic, alkaline and neutral compositions distinguished through colorimetric and electrical readouts. The mist pulse photographs show an example of a neutral mist pulse, and the fibre resistance change was recorded by applying three consecutive neutral mist pulses (normalized resistance change is calculated as \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{R}^{* }-{R}_{0}}{{R}_{0}}$$\end{document} R * − R 0 R 0 , where R* is the peak resistance and R 0 is the initial resistance; the initial resistances of the fibre arrays are in the range of 10 kΩ). a – c , Typical results from n = 5 volunteers, with n > 3 independent experiments performed on each volunteer.

Article Snippet: The gel electrodes used as references were commercial disposable ECG Electrodes (ADInstruments).

Techniques: Biomarker Discovery

a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of ECG signals acquired by fibre and gel electrodes at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).

Journal: Nature Electronics

Article Title: Imperceptible augmentation of living systems with organic bioelectronic fibres

doi: 10.1038/s41928-024-01174-4

Figure Lengend Snippet: a , An illustration (top) showing fibres covering the ridges of the fingerprints, where \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{N}{d}$$\end{document} N d indicates the number of fibres N across a distance d ; and the experimental evidence is provided by the photographs (bottom row) showing the complete fibre array on a fingertip and the zoom-in view of the fibres follow the ridges of the fingerprints (scale bars left to right, 5 mm, 500 μm). b , Contact impedance versus deposition time on the fingertip. c , Comparison of ECG signals acquired by fibre and gel electrodes at the same time (signal correlation P = 0.99). d , (i) An array of fibres deposited on the thumb muscle region, where ON/OFF loading on the thumb results in clear on/off EMG signals detected by the fibres (scale bar, 1 cm). (ii) Bar chart to depict variations in absolute EMG amplitude from the thumb muscle region against different loading weights on the thumb (data are presented as mean absolute EMG values ± standard deviation of EMG measured for around 5 s in each case). e , Facile repairability of the exposed fibre arrays. The triangular symbol indicates the impedance of the fibre arrays after being deliberately damaged by abrasion, and then new fibres are deposited on demand to repair as indicated by the circular symbols. f , The stability of exposed fibre electrode (exposed bioelectronic fibres on skin) under the conditions of (i) ambient wearing; (ii) mouse clicking; (iii) dry friction wear with a plastic surface (at a surface speed of 4 cm s −1 under around 40% relative humidity (RH) environments); (iv) simulated ‘wet’ conditions without mechanical disturbance. g , Wet friction (at a surface speed of around 4 cm s −1 ) of exposed and cellulose-based fibre protected sensing interface. h , Rinsing under running water (the sensing interface is protected with cellulose-based fibres and the fibre contact is encapsulated with a cellulose-based film) (ECG scales for f , g , horizontal time scale 1 s, vertical voltage scale 0.5 mV). ( a – e , typical results from n = 5 volunteers, f – h , typical results from n = 3 volunteers, for all experiments with n > 3 independent experiments performed on each volunteer).

Article Snippet: Individual ECG signals of both people for validation were acquired as references using commercial disposable ECG gel electrodes at the same time (ADInstruments).

Techniques: Comparison, Standard Deviation

a , Augmented touch perception via dual-ECG sensing with person-i wearing bioelectronic fibre arrays and person-ii without. The dual-ECG signal acquired through the fibre array is compared with the reconstructed composite-ECG signal from validation gel electrodes. The red downward facing and green upward facing triangles indicate the R peaks of person-i and person-ii, respectively. b , A breathable skin-gated OECT on a fingertip; the OECT displays a response time in the 60 s range. c , Dual-modal sensing for augmented perception of mist pulses with acidic, alkaline and neutral compositions distinguished through colorimetric and electrical readouts. The mist pulse photographs show an example of a neutral mist pulse, and the fibre resistance change was recorded by applying three consecutive neutral mist pulses (normalized resistance change is calculated as \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{R}^{* }-{R}_{0}}{{R}_{0}}$$\end{document} R * − R 0 R 0 , where R* is the peak resistance and R 0 is the initial resistance; the initial resistances of the fibre arrays are in the range of 10 kΩ). a – c , Typical results from n = 5 volunteers, with n > 3 independent experiments performed on each volunteer.

Journal: Nature Electronics

Article Title: Imperceptible augmentation of living systems with organic bioelectronic fibres

doi: 10.1038/s41928-024-01174-4

Figure Lengend Snippet: a , Augmented touch perception via dual-ECG sensing with person-i wearing bioelectronic fibre arrays and person-ii without. The dual-ECG signal acquired through the fibre array is compared with the reconstructed composite-ECG signal from validation gel electrodes. The red downward facing and green upward facing triangles indicate the R peaks of person-i and person-ii, respectively. b , A breathable skin-gated OECT on a fingertip; the OECT displays a response time in the 60 s range. c , Dual-modal sensing for augmented perception of mist pulses with acidic, alkaline and neutral compositions distinguished through colorimetric and electrical readouts. The mist pulse photographs show an example of a neutral mist pulse, and the fibre resistance change was recorded by applying three consecutive neutral mist pulses (normalized resistance change is calculated as \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\frac{{R}^{* }-{R}_{0}}{{R}_{0}}$$\end{document} R * − R 0 R 0 , where R* is the peak resistance and R 0 is the initial resistance; the initial resistances of the fibre arrays are in the range of 10 kΩ). a – c , Typical results from n = 5 volunteers, with n > 3 independent experiments performed on each volunteer.

Article Snippet: Individual ECG signals of both people for validation were acquired as references using commercial disposable ECG gel electrodes at the same time (ADInstruments).

Techniques: Biomarker Discovery